The energy consumption is one of the main factors lux moms in selecting the type of air conditioning system. On the other hand, to raise the level of customer satisfaction and compliance with the new rules, the energy consumption of factories also heavily involved in improving the productivity and performance of their air conditioning systems.
Reduce power consumption, easy operation and reliable performance than other HVAC products, has led to today VRF systems are recognized as one of the most efficient modern ventilation systems. Wide range of innovative features lux moms and smart technology employed in the system, and the ability to create exceptional heating and cooling, has caused VRF systems every day to find more fans in the world.
In the not too distant past most central cooling system, the types of chillers. Today, with the invention of technology VRF, every day more and more engineers will select the device type as the ventilation system. Heating and cooling capabilities by providing lux moms a fully integrated system with a single control system, no need to keep the engine room and technicians, as well as low power consumption and coefficient of performance (COP) of VRF systems, especially at partial loads, only a few of the advantages of the type system.
Mvltyvy LG VRF air conditioning systems utilize technology. The device consists of a number of internal and external unit and the capacity of 80 thousand to 800 thousand BTA Yu exist. External unit includes a condenser, compressor, intelligent brain and machine ... and a pair of sweep refrigerant pipes connected to it. But it's a pipe coupling lux moms can be multiple branches and dozens of internal units (up to 64 units), the operator plays the role as a condenser connected. Plumbing possibility of large distances, can be installed in high projects, the possibility of installing an internal units of different types, the central controller and the use of refrigerant R 410 a friendly environment as well as the need to drink water, some of the reasons for the increasing widely Engineers Counsel for the use of this system.
He coefficient of performance (COP) devices Mvltyvy 4 (in the capacity of two hundred thousand BTA U) equals 4.85 and improves efficiency at partial loads (IPLV) announced it 6 times and said this would mean 30 ~ 15% efficiency 40 ~ 20% increase in capacity and efficiency at partial loads than Mvltyvy Series 3. The reasons for this increased efficiency, new technology used in this series of devices Mvltyvy who went on to describe some of them below.
All compressors lux moms used in Mvltyvy Series 4, inverter (variable lux moms speed) and this means that the rotation speed of the compressor to reduce the amount lux moms of time needed and no longer increases the partial loads, with a maximum compressors work a. The compressors Mvltyvy 4, fourth-generation LG Askral compressors and unique features. Previous series lux moms compressor lux moms range 20 to 120 Hz. They had, however, something new series range from 15 to 150 Hz increased and this means less power consumption at partial loads and 25% increase in the compressor power.
By using steam injection technology (Vapor Injection) in the new series, the heating capacity of the system can be increased by 27% even when the ambient air temperature is 25 degrees Celsius below zero, Grmabkhsh indoor room.
LG researchers found that the proportion of the amount of refrigerant circulating in the cycle, the temperature has a significant impact on energy consumption device. lux moms For this purpose, lux moms the device is able to help Mvltyvy 4 refrigerant tank and intelligent, the amount of refrigerant in the cooling cycle based on the function, the relative decrease or increase supply or load.
In older models, each eight hours of action to recover the oil in the pipe and returns to the compressor. But there is a new technology company LG sensor units, lux moms each time the compressor oil and check the oil level only when the compressor is reduced, oil recovery starts. lux moms This will cause the number of recoverable oil has fallen sharply, resulting in savings in energy consumption.
Another result of the R & D suggests that the number of passes of the condenser tubes (refrigerant flow path) and the speed at which the refrigerant has a direct impact on system COP. To this end, the fourth lux moms series of technology LG Mvltyvy lux moms "variable number of passes" is better. This means that according to the heating or cooling of the refrigerant tubing passes the external unit and therefore the speed at which the refrigerant lux moms is variable.
This technology, in addition to increasing the efficiency of the system, also provides the opportunity to participate in projects such as sports clubs or server rooms that require lux moms cooling even in winter, even when the air temperature lux moms is lowered to 10 degrees Celsius below zero, a performance is cooling.