The first day in the heat of summer 1393 Football World Cup arrives tomorrow and certainly all of u


Saturday, Persian date Khordad 31 1393 Posted in miscellany published aidy bryant by Babak valizadeh Be the first to comment! Photo gallery of the new generation of air conditioners LG Multi V unveiled
The first day in the heat of summer 1393 Football World Cup arrives tomorrow and certainly all of us are looking for ways to head off a lot of heat. Homes and small offices that are located in buildings of three or four each as different solutions to this problem, but the situation is very serious when a large and complex set Rooms Arvbrv of the building and board it. This is the new generation of air conditioning systems, LG Multi V officially aidy bryant announced last week, will be taken Zmam Affairs and an enjoyable summer (and winter warm!) For us to strive.
Reduce power consumption, easy operation and reliable performance than other air conditioning systems, has led to today VRF systems as one of the most modern ventilation systems are known. Wide range of innovative technology and smart features aidy bryant used in these systems, and the ability to create exceptional heating and cooling, has caused VRF systems every day to find more fans in the world. New Generation aidy bryant LG Multi V systems with a focus on greater energy efficiency and customer satisfaction has been designed and developed. Multi V A + energy consumption of the new standard and is supported by a series of products aidy bryant offered in cooperation with Gldyran the domestic aidy bryant market.
In the not too distant past most central cooling system, chiller types, respectively. Today, with more engineers every day VRF technology, these devices are selected as the best ventilation. Heating and cooling capabilities by providing a fully integrated system aidy bryant with a single control system, no need to keep the engine house and technicians, as well as low power consumption and coefficient of performance (COP) of high-pressure part of the VRF, especially in the just a number of advantages This type of system is the flagship. LG's Multi VRF air conditioners also take advantage of the technology. This type of device aidy bryant includes an outer and inner unit and several thousand BTU capacity of 80 thousand to 800 are available. Kndasvr external unit includes compressor, aidy bryant brain and other intelligent devices and a pair of sweep refrigerant pipes connected to it. But it can split a pair of pipes and several dozen internal units (up to 64 units) that play a role in the evaporator, aidy bryant a condenser connected. The possibility of long distance pipeline, a project to install high, the possibility of installing an internal units, the central controller utilizes refrigerant R 410 a more environmentally friendly and also do not need to drink water, some of the reasons widely Consulting engineers for the increasing use of the system.
The coefficient of performance (COP) of his multi-device 4 (in the capacity of two hundred aidy bryant thousand BTU) equal to 4.85 and improves efficiency at part load (IPLV) is equal to 6 (this is fifteen to thirty percent efficiency at full capacity and twenty to forty percent efficiency at partial loads compared to the Multi Series 3). The reasons for this increased efficiency, new technologies used in the series of his multimedia devices. Then when you see only a part of the new capabilities and technologies aidy bryant that have been used in the Multi V IV.
1. The inverter compressors: All units used in the Multi Series 4, inverter (variable speed) and this means that the rotation speed of the compressor to reduce the amount of time needed and no longer increases at part load compressor aidy bryant with capacity to work.
2. Haypvr steam injection technology by taking advantage of the steam injection technology (Vapor Injection) in the new series, the heating capacity of the system aidy bryant can be increased by 27% even when the ambient air temperature to 25 degrees Celsius below zero is Grmabkhsh indoor aidy bryant room. Haypvr (HIPOR), a leading industrial technology aidy bryant and LG is monopolized by the return of oil at high pressure directly into the compressor, reduce the waste of energy improve the performance of the overall performance of the back.
3. Intelligent control aidy bryant the amount of refrigerant: LG researchers found that the proportion of circulating refrigerant cycle device aidy bryant with temperature has a big impact on energy consumption. He is a multi-purpose device 4 is able to help your refrigerant tank and intelligent flow of refrigerant in the cooling cycle based work, heating or time relative decrease aidy bryant or increase.
4. Oil Control Smart older models, each eight hours of action to recover oil in the pipes and returns it to the compressor. But new technology LG sensor units, each time the compressor oil and check the oil level in the compressor is reduced only when the oil begins to recover. This will cause the number of recoverable oil has fallen sharply, resulting in energy saving.
5. The number of passes in the variable condenser Another finding of the R & D suggests that the number of passes aidy bryant condenser tubes (refrigerant flow path) as well as the speed of the refrigerant in the system has a direct impact on COP. LG's fourth series of multi-purpose technology "variable number aidy bryant of passes" is a benefit. This means that according to the heating or cooling of the refrigerant pipe passes the external unit and therefore the speed at which the refrigerant aidy bryant is variable. It also increases the efficiency